Supported systems

HP 3000 Terminal Emulator: HP 700/92 and 2392A in WND Terminal

Connect to an HP 3000 with HP 700/92 or 2392A terminal settings. Work at a character-mode prompt or use host-defined keys in a block form.

Supported terminals and connections

On a small screen, swipe the table to read all columns.

Current WND Terminal host coverage and release
SystemTerminalConnectionWhere it runsCurrent scopeRelease
HP 3000 HP terminal emulationHP 700/92, HP 2392ATelnetWindows, Mac, LinuxCharacter and block forms, host-defined f1–f8 keys and basic identity/status behavior for HP 700/92 and 2392A.v1.0.319

The HP 2392A profile answers common identity and status requests. The separate HP 700/94 profile is a limited common-form starting point; model-specific VPLUS behavior still needs a customer-host check.

What the sample does

The simulated HP host accepts HELLO MGR.SYS and RUN ORDERS, then an order for A-100, quantity 7, for LONDON DEPOT.

Download the compatibility lab (Python 3 and WND Terminal required)

Connect to your host

Choose HP 3000 on the WND Terminal connect page, enter the host address and use the default Telnet port 23 unless your gateway has another port.

Read the connection guide

The software-host examples let you try these workflows now. WND Software checks your application workflows during a proof of value and addresses compatibility differences found.

Move an existing session

Bring the host address, port, terminal type, key assignments and macros used by your team. Create a WND Terminal connection with the settings above, then run the actual screens and keys your application uses. Check the session import guide for supported source formats; the connection type alone does not prove that an old profile or macro can be imported.

Test your exact terminal model.

Bring the connection settings and screens your team uses. We will agree on the workflow to prove during a free two-to-four-week proof of value.

Check HP 3000 and HP 2392A against your application

Keep a working session profile and a repeatable test case. Compare what the application receives as well as what the terminal draws. Use the software-host examples as a starting point, then record the results on the actual host before a rollout.

On a small screen, swipe the table to read all columns.

Application checkWhat to verify
Test both application modesStart with the command prompt, then open the actual block-form application. A working HELLO prompt does not prove all forms will behave correctly.
Preserve host-defined keysRecord the function labels and the operation each key performs. Compare application navigation with the current terminal instead of relying on labels alone.
Check screen transitionsUse a read-only inquiry, an editable form and a validation-error path. Confirm fields and cursor position after each host response.
Choose the intended profileHP 700/92 and 2392A settings are separate from the limited HP 700/94 profile. Select the profile required by the real application.
Verify peripheral dependenciesBring examples of printing or other peripheral behavior your workflow requires. A successful software-host form is not proof of physical-device compatibility.

Bring the host address, selected terminal type, keyboard map and the steps that reproduce a problem to a proof of value. Distinguish a simulated sample from a customer-host result in the test record. See supported systems and profile limits for the current release scope.

Keyboard and host workflow

Identify whether the application expects HP 700/92 or HP 2392A behavior before mapping the keyboard. Keep the existing host-defined function labels and the action sent by each key. Begin with a character-mode sign-on, move into a block form, edit more than one field, and use the application's normal submission key. A terminal label in the connection settings is only the beginning of this check; field selection and transmission must also match the application.

When a screen or key behaves differently

For a failed form, record the selected model, the screen before submission, the fields changed and the exact host response. Compare cursor placement after both a successful operation and an application validation error. This helps distinguish a wrong profile or key map from a business rule enforced on the HP 3000. Keep printing and peripheral checks separate from the ordinary form test, especially if an existing workflow depends on physical-device status.

Replacing an existing terminal client

An HP 3000 migration should retain a known working session while the new client is evaluated. Use the supplied software order example for a repeatable starting point, then test the application's actual commands and host-defined keys. The separate partial HP 700/94 profile has different limits; do not select it merely because its model number is newer. Document which profile was tested and the workflows that remain outside the agreed scope.

Keyboard-map documentation · Specialty terminal configuration and limits

Related terminal models

HP 700/94 Terminal Emulator: Partial Profile · NonStop 6530 Terminal Emulator · Unisys T27 and UTS Terminal Emulator

Use the supported-systems index to compare released profiles and limits. The emulator evaluation checklist covers the broader deployment decision.