# An InfoConnect alternative for your IBM, Unisys and airline users

Source: https://wndsoftware.com/compare-infoconnect

WND Terminal reads the IBM session files you already have, and connects to Unisys T27 and UTS, airline ALC, VT, HP and Tandem hosts in the same app. Tell us your hosts during the proof of value and we’ll confirm each one with you.

WND Terminal includes every feature for at most $75 per user per year, with a 100-user minimum. A proof of value takes two to four weeks. Compare your current vendor quote and migration work in the [savings calculator](https://wndsoftware.com/savings-calculator). Review updated October 23, 2026.

Check existing emulator files in WND Terminal before planning the rollout.
[See the Migration readiness report](https://wndsoftware.com/migration-readiness-report)
.
WND Terminal is an alternative to Rocket InfoConnect Desktop. It reads the `.rd3x` and `.rd5x` files InfoConnect saves for IBM mainframe (3270) and IBM i (5250) sessions, and it has Unisys T27 and UTS 60, airline ALC over MATIP, VT, HP 700/92 and Tandem 6530 terminals. Download the compatibility lab for working synthetic T27, UTS, HP, 6530 and ALC applications, then check your own host workflows during a proof of value.


## Move every group, starting with the IBM users

InfoConnect Desktop is sold in editions for Unisys and for airlines, and both include IBM 3270 and 5250 sessions. WND Terminal covers the IBM part and the other terminals too.


### IBM 3270 and 5250 users

Move first. Their sessions are `.rd3x` and `.rd5x` files, which WND Terminal reads as they are.


### Unisys T27 and UTS users

WND Terminal has T27 and UTS 60 terminals, with their own keys and status line. Set the connections up in IT’s policy, and confirm each host with us during the proof of value.


### Airline ALC users

ALC agent sets over MATIP, with ASCII or EBCDIC characters. Hosts that need IPARS coding aren’t supported. We confirm your host with you during the proof of value.


### VT, HP and Tandem users

VT100 to VT320 over SSH or Telnet, HP 700/92 and Tandem 6530. VT sessions import from InfoConnect’s `.rdox` files. See [Unisys, HP, Tandem and airline hosts](https://wndsoftware.com/docs/other-terminals).

At renewal, you license InfoConnect only for anyone still waiting on a host check. Everyone else is on WND Terminal at up to $75 per user per year.


## Which InfoConnect host are you moving?

WND Terminal's current tagged terminal inventory lists the established and scoped model profiles below. InfoConnect Desktop Pro has separate Unisys and Airlines product paths; a host name alone does not identify every terminal setting or printer workflow. Test the application screens and keys used by each group.

On a small screen, swipe the table to read all columns.


| Host and terminal | WND Terminal current scope | Rocket InfoConnect scope |
| --- | --- | --- |
| IBM Z 3270 / IBM i 5250 | 3270, TN3270E and 5250 profiles over Telnet or TLS. | InfoConnect Desktop Pro documents IBM Z and IBM i sessions. |
| UNIX and Linux VT | VT100, VT220, VT320 and xterm-compatible behavior over SSH or Telnet, plus scoped VT52/VT102 and partial VT420/VT520 profiles over Telnet. | VT is documented for InfoConnect Desktop Pro; check the terminal model in your session. |
| Unisys MCP / OS 2200 | T27 and UTS 60 over Telnet. Run XMIT, SPCFY, formatted fields and message waiting in the included samples. | InfoConnect Desktop Pro for Unisys documents T27 and UTS. Verify your path and programmed keys. |
| Wyse, IBM 3151 and PC ANSI families | Scoped Telnet profiles for WY-50/WY-50+/WY-60, IBM 3151 echo mode, BBS ANSI/CP437, SCO ANSI and AT386. See each profile limit in [supported systems](https://wndsoftware.com/supported-systems). | Verify the exact Rocket product, terminal type and license in your estate. |
| HP 3000 / HPE NonStop | HP 700/92 or 2392A, partial HP 700/94 and NonStop 6530 over Telnet. Check each application's host interrogation and page behavior. | InfoConnect Desktop Pro for Airlines lists HP 3000 and HP NonStop access; verify the installed terminal component. |
| Airline reservations | P1024B ALC agent sets over MATIP type A, using ASCII or EBCDIC. | InfoConnect Desktop Pro for Airlines documents TPF/ALCS host access and airline configuration. |
| Airline printers and readers | Software-only virtual ATB/BTP routing, synthetic reader and bounded ZPL sample tag; physical devices and IATA/AEA protocols need a customer trial. | InfoConnect's airline product describes print delivery; the InfoConnect Enterprise PTR is a separately licensed product. Inventory each device. |
| Migration | Read supported .rd3x, .rd5x and .rdox sessions; set up specialty connections and check macros individually. | Existing InfoConnect sessions run in their licensed client; do not assume their files transfer unchanged to another emulator. |
| Central and browser access | IT policy for desktop sessions; browser gateway for supported IBM and VT profiles. Specialty profiles are desktop-only in this inventory. | Desktop Pro is a Windows client. Rocket MSS and web host-access products are separate deployment choices. |

[Review WND Terminal's exact profiles and limits](https://wndsoftware.com/supported-systems) · [Download the five-host starter lab](https://wndsoftware.com/downloads/wnd-compatibility-lab.zip) · [Run sixteen model sample hosts](https://wndsoftware.com/downloads/wnd-model-samples.zip). The lab uses synthetic hosts; it does not certify your hardware or airline devices.

Rocket sources: [InfoConnect Desktop Pro for Unisys](https://www.rocketsoftware.com/sites/default/files/resource_files/infoconnect-desktop-pro-for-unisys.pdf), [InfoConnect Desktop Pro for Airlines](https://www.rocketsoftware.com/sites/default/files/resource_files/infoconnect-desktop-pro-for-airlines.pdf), [InfoConnect Enterprise for Airlines and PTR](https://www.rocketsoftware.com/sites/default/files/resource_files/ent-air.pdf) and [MSS](https://www.rocketsoftware.com/sites/default/files/resource_files/host-access-management-security-server.pdf) and [Secure Host Access tiers](https://www.rocketsoftware.com/en-us/products/secure-host-access), reviewed October 20, 2026.


## At a glance

WND Terminal facts come from its documentation. InfoConnect facts come from Micro Focus and Rocket. A check means the feature is in that product’s public documentation.

On a small screen, swipe the table to read all columns.


| Capability | WND Terminal | InfoConnect Desktop (Rocket) |
| --- | --- | --- |
| IBM Z mainframe (3270, TN3270E) | Yes | Yes |
| IBM i (5250) display | Yes | Yes |
| Unisys T27 and UTS | Yes 1 | Yes |
| Airline ALC | Yes 1 | Yes |
| VT, HP and Tandem 6530 | Yes 1 | Yes 2 |
| Windows | Yes | Yes |
| Mac | Yes | Not found in public documentation |
| Browser access (WND Terminal 3270, 5250 and VT) | Yes | Yes 3 |
| Reads InfoConnect’s IBM session files (`.rd3x`, `.rd5x`) | Yes | Yes |
| VBA, CASL and Extra! Basic macros | Yes 4 | Yes |
| Screen history | Yes | Yes |
| Recent typing and autocomplete | Yes | Yes |
| Card-number and pattern masking | Yes | Yes |
| Audit log to Splunk or CEF/syslog | Yes | Not found in public documentation |
| AI that explains the screen | Yes | Not found in public documentation |
| AI that works the session for you | Yes | Not found in public documentation |
| [Terminal access from ChatGPT or Claude (MCP)](https://wndsoftware.com/ai#mcp-access) | Yes | Not found in public documentation |
| Error and abend hints on screen | Yes | Not found in public documentation |
| Response times to OpenTelemetry | Yes | Not found in public documentation |
| Fleet discovery and first-run import | Yes | Not found in public documentation |
| Print routing to folder, email and PDF | Yes | Not found in public documentation |
| Session handoff between windows of one sign-in (browser) | Yes | Not found in public documentation |
| Help desk joins a live session with consent (browser) | Yes | Not found in public documentation |
| Screen translation | Yes 5 | Not found in public documentation |
| VS Code extension | Yes | Not found in public documentation |
| Published VPAT | Yes | Not found in public documentation |
| Price published on the website | Yes | Not found in public documentation |
| [Terminal screen translation with deployable language packs](https://wndsoftware.com/terminal-translation) | Yes |  |
| [Screen Access: restrict host applications, screens and field values by role](https://wndsoftware.com/screen-access) | Yes |  |
| [Real User Monitoring in Gateway: operator wait and host response](https://wndsoftware.com/response-time-monitoring) | Yes |  |
| [Guided learning and operator onboarding on live screens](https://wndsoftware.com/guided-training) | Yes |  |
| [Modern view of live host screens](https://wndsoftware.com/modern-view) | Yes |  |
| [Ask WND lookups from approved external MCP tools](https://wndsoftware.com/ai#mcp-access) | Yes |  |
| [AI answers with citations from company runbooks](https://wndsoftware.com/ask-wnd) | Yes |  |

- Built from the vendors’ public manuals and tested against simulated hosts. We confirm your host with you in the proof of value.
- Depends on edition and add-on.
- Through Rocket Secure Host Access Anywhere, sold separately.
- Extra! Basic, and VBA in `.rd3x` and `.rd5x` documents or exported `.bas` modules. CASL macros aren’t run.
- In Modern view. From your glossary first, and an AI model when IT allows it.

Checks come from each vendor’s publicly available documentation, as of October 2026. A blank cell means we found no public documentation for that feature. Products change, so check with the vendor to confirm before you decide. The vendor pages behind the checks include [InfoConnect masking](https://www.microfocus.com/documentation/infoconnect-desktop/18-0/guides/protecting-data-and-information-privacy/protecting-sensitive-data.html), [Secure Host Access Anywhere](https://www.rocketsoftware.com/en-us/products/secure-host-access/anywhere), [InfoConnect screen history](https://www.microfocus.com/documentation/infoconnect-desktop/18-0/guides/save-and-use-screen-history/index.html) and [InfoConnect auto complete](https://www.microfocus.com/documentation/infoconnect-desktop/18-0/guides/productivity-tools/configure-auto-complete-dialog-box.html).

InfoConnect facts come from the InfoConnect Desktop documentation and Rocket’s own data sheet, linked at the foot of this page.


## What moves, and what needs a person

InfoConnect Desktop saves IBM sessions in the same file types as Reflection Desktop. The Unisys, airline and older InfoConnect sessions are set up again in WND Terminal.

On a small screen, swipe the table to read all columns.


| InfoConnect file | What it holds | With WND Terminal |
| --- | --- | --- |
| `.rd3x` | IBM 3270 session | Read directly. It’s the same session document type Reflection Desktop uses |
| `.rd5x` | IBM 5250 session | Read directly, as above |
| `.rdox` | VT session | Imported as a UNIX and Linux (VT) connection, as Reflection’s `.rdox` files are |
| `.rsf` | 3270 and 5250 printer session | Needs a person.  WND Terminal runs 3287 and IBM i printer sessions, so they’re set up again in the policy |
| `.it27`, `.iuts`, `.ialc` | Unisys T27, UTS and airline ALC sessions | Set up again.  These files aren’t read. Add the T27, UTS or ALC connections in WND Terminal or IT’s policy, and confirm each host with us during the proof of value |
| `.adp`, `.idp` | Older InfoConnect sessions | Not read.  Needs a person |
| `vbaProject.bin` | VBA macros in the common project | Export the modules.  Save them as `.bas` files from the VBA editor, and WND Terminal runs those written for IBM sessions as they are |
| `.ebm` | Extra! Basic macros | Run as they are. The Migration readiness report checks each one |
| `.xwc`, `.xws` | CASL macros, compiled and source | Not run.  Needs a person |

Point the Migration readiness report at the IBM sessions in the first week of the proof of value. It sorts each file into “imports cleanly,” “imports with small notes” or “needs a person.” Copies of the same session become one connection, and the result is written as a policy.


## What changes when you move

- Room to retire InfoConnect. WND Terminal now has the listed Unisys, airline and VT terminal profiles alongside IBM sessions. Groups with airline devices, unsupported transport or automation needs move after those paths are verified. The usage dashboard shows who used WND Terminal in the last 30, 60 and 90 days, so you can count seats before renewal.
- No rebuild for the IBM sessions. InfoConnect Desktop’s `.rd3x` and `.rd5x` files are read as they are, with host, port, device name, screen size and host code page.
- People on a Mac or Linux. A native app for Apple Silicon and Intel Macs, managed with Jamf, Intune, Kandji or Mosyle, and packages for Linux desktops. The Home Depot moved 2,800 Mac users off Citrix with the Mac app.
- Help for people who don’t know the host. Ctrl+E explains the code or message on the screen. Nationwide cut mainframe service-desk tickets by 40% with it.
- Evidence for audit. Masking of card numbers and your own patterns, an audit log to Splunk or CEF/syslog, and tamper-evident recording of privileged sessions.
- Honest gaps. CASL macros aren’t run, and VBA written for Unisys or airline sessions needs a person. The Unisys, airline, HP and Tandem terminals were built from public manuals. Tell us your hosts during the proof of value and we’ll confirm each one with you.


## What customers changed when they switched

From WND Terminal’s published customer stories. The stories don’t name the previous vendor.

- [Nationwide](https://wndsoftware.com/case-study-nationwide)40% fewer mainframe service-desk tickets.
- [Union Pacific](https://wndsoftware.com/case-study-union-pacific)1,900 session profiles and 340 keyboard maps imported. 7,800 users moved in eight weeks, against a nine-month estimate.

Renewal context from the same stories. The Home Depot had 12% at its last renewal. Union Pacific had 10% plus a five-year commitment.


## Other comparisons

[WND Terminal vs. Reflection Import .rd3x and .rd5x sessions. Add Mac and the browser without Citrix. Compare →](https://wndsoftware.com/compare-reflection)
[WND Terminal vs. Extra! X-treme Read Extra! .edp sessions directly, with their backup hosts. Compare →](https://wndsoftware.com/compare-extra)
[WND Terminal vs. Rumba Rumba profiles through Reflection Desktop. Full 5250 for IBM i. Compare →](https://wndsoftware.com/compare-rumba)
[WND Terminal vs. HostExplorer From Hummingbird to OpenText to Rocket. What moves and what needs a person. Compare →](https://wndsoftware.com/compare-hostexplorer)
InfoConnect facts on this page come from [Files Used by InfoConnect](https://www.microfocus.com/documentation/infoconnect-desktop/18-0/guides/admin-guide/appendix/files-used-by-infoconnect.html) and the [InfoConnect Desktop 18.0 release notes](https://microfocus.com/documentation/infoconnect-desktop/18-0-2/guides/introduction/release-notes.html) (Micro Focus documentation), [Rocket’s InfoConnect Desktop Pro for Airlines data sheet](https://www.rocketsoftware.com/sites/default/files/resource_files/infoconnect-desktop-pro-for-airlines.pdf), the [Rocket Secure Host Access product page](https://www.rocketsoftware.com/en-us/products/secure-host-access) and [IT Jungle, February 2025](https://www.itjungle.com/2025/02/10/rocket-consolidates-half-a-dozen-terminal-emulators-with-secure-host-access/), checked in October 2026.

InfoConnect, Reflection, Extra!, Rumba and BlueZone are trademarks of Rocket Software. Unisys is a trademark of Unisys Corporation. IBM and IBM i are trademarks of IBM. WND Software is not affiliated with or endorsed by these companies.


## Questions


### Does WND Terminal support Unisys T27 or UTS?

Yes. WND Terminal has T27 and UTS 60 terminals, with their own keys and status line. They were built from the public manuals and tested against simulated hosts, so tell us your host during the proof of value and we’ll confirm it with you.


### Can WND Terminal import InfoConnect sessions?

It reads the .rd3x (3270), .rd5x (5250) and .rdox (VT) files InfoConnect Desktop saves, the same way it reads Reflection Desktop documents. Older .adp and .idp files and the Unisys and ALC session files are not read, so those connections are set up in WND Terminal or IT’s policy.


### Should we replace InfoConnect completely?

Move the IBM users first, then each Unisys, airline, VT, HP or Tandem group after its host and application workflows are confirmed. Airline printers, readers and any unsupported transport need a separate compatibility plan.


### What happens to our InfoConnect VBA macros?

VBA macros in .rd3x and .rd5x documents, and modules exported as .bas files, run as they are when they’re written for IBM sessions. CASL macros and VBA written for Unisys or airline sessions need a person.


## How should we evaluate WND Terminal against Rocket InfoConnect?

Start with the exact host protocol, deployment and workflows covered by your current product. Have a user complete sign-on, an ordinary transaction, a rejected entry and cancellation with the familiar keys. Test printing, file transfer and actual automation separately where used. For browser delivery, include gateway and identity administration in the comparison; for an application-modernization project, include the required interface work. A successful connection alone does not establish an equivalent replacement.

Check [WND Terminal’s supported profiles and limits](https://wndsoftware.com/supported-systems), [current plan scope and pricing](https://wndsoftware.com/pricing), and the [migration evaluation steps](https://wndsoftware.com/switch).


## Plan a mainframe emulator evaluation

Use the [3270 and TN3270 emulator guide](https://wndsoftware.com/3270-terminal-emulator) to check host connections, keys, printing and deployment. For a customer example of managed agency deployment, read [Texas HHSC’s story](https://wndsoftware.com/case-study-texas-hhsc). That story does not name the previous emulator vendor; it is evidence of the workflow, not a claim that this customer replaced the product compared here.

[Compare the wider 3270 emulator shortlist](https://wndsoftware.com/3270-emulator-alternatives).
